Machine Type | Connection via | Details |
Tajima machine with a Serial Port | Serial Cable: – Type Q (25 to 25 pin) – Type R (9 pin PC to 25 pin embroidery machine) | Port=COM1/COM2 Protocol=Standard Serial Baud=9600, or 38400 Data bits=8 Stop bits=1 Parity=None Handshaking=Hardware |
Machine Type | Connection via | Details |
Tanto, BEAT, BEVT, BEXY, BEXR | Serial Cable (9 pin) supplied by Barudan | Port=COM1/COM2 Protocol=Standard Serial Baud=9600, or 38400 Data bits=8 Stop bits=1 Parity=None Handshaking=Embroidery Machine |
BEMS/R, BENS/R, BEZN, BEMAX, BEDS | Serial Cable (25 pin) supplied by Barudan | Port=COM1/COM2 Protocol=Standard Serial Baud=9600 Data bits=8 Stop bits=1 Parity=None Handshaking=Embroidery Machine |
Machine Type | Connection via | Details |
AD800/820/820A/830/850/860, ESP9000, ESP9100 | Serial Cable Type G, H, U, or V | Port=COM1/COM2 Protocol=Toyota Serial Baud=9600, or 38400 Data bits=8 Stop bits=2 Parity=Odd Handshaking=Hardware |
Alternative settings for AD850/860 | Serial Cable Type G, H, U, or V | Port=COM1/COM2 Protocol=Toyota Serial Baud=9600, or 38400 Data bits=8 Stop bits=2 Parity=None Handshaking=Embroidery Machine |
Machine Type | Connection via | Details |
Professional machines except 6-head | Serial Cable – Type H | Port=COM1/COM2 Protocol=Standard Serial Baud=9600 Data bits=8 Stop bits=1 Parity=None Handshaking=Embroidery Machine |
Brother 6-head | Special Controller Board, Cable and Software from Brother | Not applicable |
Machine Type | Connection via | Details |
HCG / HCG-B / HCA (controller HMS702C and HMS802) | Serial Cable: – Type G (25 to 25 pin) – Type U (9 pin PC to 25 pin embroidery machine) | Port=COM1/COM2 Protocol=Standard Serial Baud=9600 Data bits=8 Stop bits=1 Parity=None Handshaking=Embroidery Machine |
HCS | Serial cable is supplied with the embroidery machine | Port=COM1/COM2 Protocol=Standard Serial Baud=38400 Data bits=8 Stop bits=1 Parity=None Handshaking=Hardware OR Embroidery Machine (both work) Machine Format=Happy or Tajima |
HCD2 | Connection Manager via Happy LAN | Connection Manager |
HCR2 | Connection Manager via Happy LAN or Happy Link | Connection Manager |
Machine Type | Connection via | Details |
SWF machines with a Serial Port | Serial Cable – Type V (9 pin) | Port=COM1/COM2 Protocol=Standard Serial Baud=38400 Data bits=8 Stop bits=1 Parity=None Handshaking=Hardware |
Machine Type | Connection via | Details |
Ricoma | Connection Manager via Ricoma PC Communication Software | Connection Manager |